<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Creekside Environmental Consulting, LLC &#187; Process Control Chemistry</title>
	<atom:link href="http://www.creeksideenvironmental.com/projects/process-control-chemistry/feed" rel="self" type="application/rss+xml" />
	<link>http://www.creeksideenvironmental.com</link>
	<description></description>
	<lastBuildDate>Fri, 20 Jan 2012 02:08:14 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=</generator>
		<item>
		<title>Storm Water Treatment Studies and Monthly Monitoring</title>
		<link>http://www.creeksideenvironmental.com/projects/storm-water-treatment-studies-and-monthly-monitoring.htm</link>
		<comments>http://www.creeksideenvironmental.com/projects/storm-water-treatment-studies-and-monthly-monitoring.htm#comments</comments>
		<pubDate>Sun, 31 May 2009 17:40:00 +0000</pubDate>
		<dc:creator>Brent Jorgensen</dc:creator>
				<category><![CDATA[Environmental Compliance]]></category>
		<category><![CDATA[Industrial Waste Treatment]]></category>
		<category><![CDATA[Laboratory Data Collection & Interpretation]]></category>
		<category><![CDATA[Past Projects]]></category>
		<category><![CDATA[Process Control Chemistry]]></category>

		<guid isPermaLink="false">http://creekside.davidmihm.com/?p=309</guid>
		<description><![CDATA[Collected storm water samples, prepared and initiated a monthly monitoring program, evaluated laboratory test results, conducted treatability tests using neutralizing agents such as sodium bisulfate, attempted bioremediation treatment with tannic acid, and completed and submitted quarterly reports required by the Oregon Department of Environmental Quality (DEQ).]]></description>
			<content:encoded><![CDATA[<h3>Kinder Morgan Bulk Terminals, Port of Portland, Oregon. </h3>
<p>Collected storm water samples, prepared and initiated a monthly monitoring program, evaluated laboratory test results, conducted treatability tests using neutralizing agents such as sodium bisulfate, attempted bioremediation treatment with tannic acid, and completed and submitted quarterly reports required by the Oregon Department of Environmental Quality (DEQ).</p>
]]></content:encoded>
			<wfw:commentRss>http://www.creeksideenvironmental.com/projects/storm-water-treatment-studies-and-monthly-monitoring.htm/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Design of Wastewater Treatment Systems, Manufacturer</title>
		<link>http://www.creeksideenvironmental.com/projects/design-wastewater-treatment.htm</link>
		<comments>http://www.creeksideenvironmental.com/projects/design-wastewater-treatment.htm#comments</comments>
		<pubDate>Sun, 31 May 2009 16:55:09 +0000</pubDate>
		<dc:creator>Brent Jorgensen</dc:creator>
				<category><![CDATA[Industrial Waste Treatment]]></category>
		<category><![CDATA[Past Projects]]></category>
		<category><![CDATA[Previous Projects (Jan 1990 - June 1998)]]></category>
		<category><![CDATA[Process Control Chemistry]]></category>

		<guid isPermaLink="false">http://creekside.davidmihm.com/?p=254</guid>
		<description><![CDATA[Confidential Electromechanical Parts Manufacturer Owner/Principal Brent Jorgensen Served as Process Control Chemist/Environmental Engineer. The facility had a silver cyanide electroplating operation and was discharging a 25 parts per million (ppm) cyanide rinse to the local POTW. Treatment included silver recovery and cyanide destruct system using sodium hypochlorite reduction. Metal effluent concentrations were reduced 96 percent.]]></description>
			<content:encoded><![CDATA[<h3>Confidential Electromechanical Parts Manufacturer<br />
Owner/Principal Brent Jorgensen Served as Process Control Chemist/Environmental Engineer.</h3>
<p>The facility had a silver cyanide electroplating operation and was discharging a 25 parts per million (ppm) cyanide rinse to the local POTW. Treatment included silver recovery and cyanide destruct system using sodium hypochlorite reduction. Metal effluent concentrations were reduced 96 percent.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.creeksideenvironmental.com/projects/design-wastewater-treatment.htm/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

